Case 155MMSHELL-RWS1
Description
No stability issues. Probability assigned to this case: 1.01 %
Warhead
Warhead: | 155MMSHELL |
Explosive: | TNT |
Explosive mass: | 7.0 kg |
Casing mass: | 36.4 kg |
Detonation location
Compartment: | RWS1 |
Coordinates: | X = 45.00 m, Y = 4.10 m, Z = 7.12 m |
Operational readiness
Operational Readiness Level after hit: | ORL3 |
Floating position indicative level: | F1 |
Floating position description: | No stability issues |
Heel: | 0.00 ° |
System level: | S3 |
Critical systems remaining: | 77.4 % |
Non-critical systems remaining: | |
Systems remaining (critical or not): | 77.4 % |
Equipment remaining: | 100.0 % |
Compartment damage level: | C2 |
The share of compartment volume not damaged: | 80.8 % |
Compartments remaining: | 90.9 % |
Structural Damage
Fragment Damage
Pressure Damage
Pressure damaged compartments: | 4 |
Fragmentation damaged compartments: | 9 |
Flooded compartments: | 0 |
Total damaged compartments: | 9 |
List of damaged compartments
ID | Description | Damage type |
---|---|---|
RWS1 | workshop | Pressure, fragmentation |
RCOR5 | Pressure, fragmentation | |
RHANGAR | hangar | Pressure, fragmentation |
HGST1 | hangar store 1 | Pressure, fragmentation |
RECR1 | Engine controm room 1 (A) | Fragmentation |
RMSW2 | main switchboard 1 | Fragmentation |
RSTO4.P | Storage space reservation | Fragmentation |
RSTO5 | Storage | Fragmentation |
RERFORE | engine room fore | Fragmentation |
Equipment Damage
No damage to equipment.
Damage to Routes
ID | Lost, cause |
---|---|
BRI-POD2 | killed:frag/ |
BRI-Waterjet control | killed:frag/ |
Gen3-swb | killed:frag/ |
BRI to ENG2 | killed:frag/ |
Damage to Systems
Name | ID | Parent system | Redundancy groups | Critical? | Lost, cause | Repairable, cause |
---|---|---|---|---|---|---|
BRI-Pod2 | BRI-Pod2 | Pod2 | Yes | fragments | ||
BRI-Waterjet | BRI-Waterjet | Water jet | Yes | fragments | ||
Pod2 | Pod2 | EL propulsion | EL propulsion Pods RG | Yes | fragments | |
Gen3 PROP | Gen3 PROP | EL propulsion | EL propulsion Gensets RG | Yes | fragments | |
Eng2 | Eng2 | Yes | fragments | |||
Main engine 2 | Main engine 2 | Water jet | Water jet Engine RG | Yes | fragments | |
Water jet | Water jet | Propulsion | Propulsion RG | Yes | fragments |
Floating Position
No stability issues.
Initial | After hit | |
---|---|---|
Draught: | 4.00 m | 4.00 m |
Trim: | 0.00 m | 0.00 m |
Heel: | 0.00 ° | 0.00 ° |
GM: | 4.72 m | 4.73 m |
Floating position after hit:
GZ Curve
GZ curve after hit:
Longitudinal Strength Curves
Longitudinal strength curves after hit: